Reinforced 3-Way Latex Hematuria Urine Catheter
Features
- Made of imported medical grade natural latex
- Silicone coating or hydrophilic coating
- Color coding size identification and recognition
- Available with soft rubber valve & hard plastic valve
- Thicker designing for tube's backside
- Providing continuous irrigation
- Reinforced design with nylon spiral integrated in catheter shaft to provide large flow rate and anti-collapsing or block when doing suction with stronger negative pressure for blood clot
- Length 40cm
Usage: prostatectomy, prostate cancer surgery, bladder cancer resection and urinary surgery operation.
Reinforced 3-Way Latex Hematuria Urine Catheter is a superior medical device. Crafted with precision from high-quality medical grade natural latex, this catheter provides optimal safety and comfort for individuals in need of urinary intervention.
The Catheter guarantees the highest standard of safety and hygiene. Reinforced type provides bigger lumen for liquid clot draining.
Contraindication
Patients with serious urethritis, serious urethral stricture, acute prostatitis, suspected with blunt or penetrating trauma-related urethral rupture shall be prohibited to use.
Warnings
- For single product and patient use only.
- Do not use product if the package is damaged.
- Do not re-use, reprocess or re-sterilize. Reuse may lead to infection. Reprocessing or Re-sterilization may damage the catheter and affect its integrity which when re-used may lead to possible deterioration in health and safety of patients.
Precautions
- Please read the instruction carefully before use.
- This procedure must be carried during complete aseptic technique.
- The catheter is for single use.
- Do not use catheter when it expires.
- Only the medical persons are allowed for operation.
- A lubricant containing petroleum base can not be used.
- The three-way catheter should not be used more than 7 days.
- Catheterization process should be aseptic.
- For three-way catheter, the balloon should be inflated with sterile water and the inflated water can't exceed the marked volume.
Directions for use
Prepare the catheter for patient use
1. Remove catheter from its sterile pouch using an aseptic technique visually inspect the catheter for any mechanical damage. If a trial inflation of the balloon is carried out ensure the balloon to insertion. Only sterile water should be used to fill the balloon.
Insert and remove the catheter
2. Inform patient or their family the cause to use foley catheter, use methods, possible discomfort, methods to ease discomfortable symptom , possible complication and nursing after catheterization.
3. Check size and specification if it is correct, check the package and balloon whether they are damaged.
4. Inform patient to take a deep breath when insert the catheter. Before use of the product, wash hands thoroughly with soap and water.
5. Connect the catheter with urine bag and release the foley catheter.
6. Disinfect the patient's perineum.
7. Choose right lubricant to lubricate the catheter.
8. Insert the foley catheter gently. When urine start comes out, insert 5cm~6cm more.
9. Inflate the balloon with appropriate volume sterile water, pull out the catheter gently until you feel resistance.
Remove the catheter
1. Explain the procedure to the patient.
2. Before catheter removal, wash hands thoroughly with soap and water and wear clean gloves.
3. Position patient and place waterproof pad under patient.
4. To deflate catheter balloon: Push a syringe without needle into the valve. Back off luer lock or slip tip syringe to 0.5mL and insert into the inflation port. Allow the pressure within the balloon to force the plunger back and fill the syringe with water (if slow or no deflation is noticed, re-seat the syringe gently).Use only gentle aspiration to encourage deflation if needed as vigorous aspiration may collapse the inflation lumen, preventing balloon deflation.
5. If the balloon doesn't deflate and permitted by hospital protocol, the valve arm may be severed. If this fails, contact adequately trained professional for assistance, as directed by hospital protocol.
6. If balloon rupture occurs, care should be taken to assure that all balloon fragments have been removed from the patient.
7. Deflate the balloon by inserting the syringe into the inflation valve, close the catheter or urine bag and gently pull out the catheter.
Product safe disposal
Used Catheter and its handling of accessories should be disposed in sanitary container to prevent possible contamination and cross infection.
Storage
Store at room controlled temperature. Do not expose to organic solvents, ionizing radiation or ultraviolet light.
1. Why choose us?
We have complete certificate CE/ISO/FSC etc. We are a good brand and have Competitive price & Fast leading time. Best service & Good reputation.
2. How can get your samples?
We provide free samples if the sample value is not much.
3. How fast can we get the goods?
Usually the production time is 30 days.
4. Can you do OEM printing?
Yes, we can offer OEM service. You can also choose Kind Rain brand or neutral English packing.
5. What services can we provide?
Accepted Delivery Terms: FOB, CFR, CIF, EXW. Accepted Payment Currency: USD, EUR, CNY. Accepted Payment Type: T/T, L/C, Western Union/Paypal/Credit card.
6. How can you do the quality control?
We had a professional QC team, which experience over 10 years. They take every progress controlled.