Type: Anesthesia & Respiratory
Material: Medical-Grade PVC
Ethylene Oxide Sterilization: Ethylene Oxide Sterilization
Quality Guarantee Period: 5 Years
Group: Adult
Logo Printing: With Logo Printing
Samples:
US$ 3.0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2024

Suppliers with verified business licenses

Guangdong, China
Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 30 days
Quality Assurance
The supplier provides quality assurance
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
to see all verified strength labels (18)
  • Overview
  • Product Description
  • Product Specification
  • Product Picture
  • Hot Products
  • Certificate Display
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
72H L-Type 10Fr - 16Fr
Product Name
72h Closed Suction System L-Type
Size
10fr -16fr
Certifications
CE/ISO Compliant
Box Specification
64 X 33 X 52 Cm
Customization
Available
Storage Conditions
Keep in a Dry,Well-Ventilated,and Cool Environment
Packaging Details
1PC/Blister Bag, 10PCS/Box, 100PCS/CTN
Transport Package
Corrugated Box
Trademark
Kind Rain
Origin
Guangdong, China
HS Code
9018390000
Production Capacity
1000000 PCS/Month

Product Description

Product Description

Closed suction system is commonly used in medical environments to suction sputum or secretions from patients' respiratory tracts while maintaining a closed environment, thereby reducing the risk of cross-infection. It typically includes suction catheters, suction machines, and closed tubing and containers connecting them, ensuring that sputum does not leak into the environment throughout the suctioning process.
 

Product Specification

Features
  • Automatic Flushing
  • 72H
  • Double Swivel Elbow
  • L-Type
  • Automatic flushing closed suction system is the catheter that retracts within an isolated turbulent cleaning chamber. This reduced colonization may help reduce of VAE and VAP in your ventilated patients.
  • Turbulent cleaning chamber creates cleansing action, resulting in a cleaner catheter.
  • Hinged valve isolates catheter tip and helps prevent inadvertent lavage.
     
    Size(I.D.) Model
    10Fr Adult/72h/Endotracheal
    12Fr Adult/72h/Endotracheal
    14Fr Adult/72h/Endotracheal
    16Fr Adult/72h/Endotracheal
    10Fr Adult/72h/Tracheostomy
    12Fr Adult/72h/Tracheostomy
    14Fr Adult/72h/Tracheostomy
    16Fr Adult/72h/Tracheostomy

    Contraindication
    Patients with Serious breathing difficulties, respiratory tract and injury are prohibited to use.

    Directions for use
    1. Prepare the closed suctioning system, suction machine, sterile gloves, mask, and other equipment. Ensure the suction machine is in good working condition.
    2. Check if the suction catheter, connecting tubes, negative pressure control valve, and other components are intact and in good condition.
    3. Evaluate the patient's consciousness, respiratory status, amount and consistency of secretions, and determine the need for suctioning.
    4. Ensure the patient can tolerate the suctioning procedure. If necessary, provide appropriate sedation or analgesia.
    5. Connect the closed suction catheter to the suction port of the suction machine, ensuring a secure connection.
    6. Ensure the valve on the suction catheter is closed to prevent air leaks or mishandling.
    7. Put on sterile gloves and a mask to maintain a sterile field during the procedure.
    8. Clean the patient's mouth and airways, removing secretions and foreign matter to facilitate suctioning.
    9. Turn on the suction machine and insert the suction catheter into the airway, typically inserting it 25-30cm into the tracheal tube until resistance is felt. Withdraw the catheter by 1-2cm.
    10. Press the suction valve with your thumb while withdrawing the catheter in a spiral motion. The suctioning time should generally not exceed 15 seconds.
    11. Observe the patient's response and the secretions during suctioning. Stop the procedure if any abnormalities are noted.

    Cautions
    1. This product is disposable products, prohibit re-use and use the expired products, read the instructions carefully before use;
    2. This product is only for operational use by nursing staff;
    3. The product is sterilized by ETO, prohibited to use if packaging is damaged;
    4. Maintain sterile technique throughout the procedure to prevent cross-contamination.
    5. Select appropriate suction catheter size and length, as well as suction negative pressure and force, based on the patient's condition and clinical needs.
    6. Avoid excessive suctioning to prevent injury to the airway mucosa or other complications.
    7. After use, the product and packaging should be disposed according to hospital or environmental requirements.
    Product safe disposal
    Used Closed suction system and its handling of accessories should be disposed in sanitary container to prevent possible contamination and cross infection.

    Storage condition
    Store in a dry, ventilated, cool place, avoid contacting with harmful substances.
     

    Product Picture

    CE Approval PVC Single-Use L-Type Closed Suction System 72h Closed Circuit SuctionCE Approval PVC Single-Use L-Type Closed Suction System 72h Closed Circuit SuctionCE Approval PVC Single-Use L-Type Closed Suction System 72h Closed Circuit SuctionCE Approval PVC Single-Use L-Type Closed Suction System 72h Closed Circuit SuctionCE Approval PVC Single-Use L-Type Closed Suction System 72h Closed Circuit SuctionCE Approval PVC Single-Use L-Type Closed Suction System 72h Closed Circuit Suction

    Hot Products

    CE Approval PVC Single-Use L-Type Closed Suction System 72h Closed Circuit Suction CE Approval PVC Single-Use L-Type Closed Suction System 72h Closed Circuit Suction CE Approval PVC Single-Use L-Type Closed Suction System 72h Closed Circuit Suction CE Approval PVC Single-Use L-Type Closed Suction System 72h Closed Circuit Suction
    CE Approval PVC Single-Use L-Type Closed Suction System 72h Closed Circuit Suction CE Approval PVC Single-Use L-Type Closed Suction System 72h Closed Circuit Suction CE Approval PVC Single-Use L-Type Closed Suction System 72h Closed Circuit Suction CE Approval PVC Single-Use L-Type Closed Suction System 72h Closed Circuit Suction

    Certificate Display

    CE Approval PVC Single-Use L-Type Closed Suction System 72h Closed Circuit Suction

    Packaging & Shipping

    CE Approval PVC Single-Use L-Type Closed Suction System 72h Closed Circuit Suction

    FAQ

    1. Why choose us?

    We have complete certificate CE/ISO/FSC etc. We are a good brand and have Competitive price & Fast leading time. Best service & Good reputation.

     

    2. How can get your samples?

    We provide free samples if the sample value is not much.

     

    3. How fast can we get the goods?

    Usually the production time is 30 days.

     

    4. Can you do OEM printing?

    Yes, we can offer OEM service. You can also choose Kind Rain brand or neutral English packing.

     

    5. What services can we provide?

    Accepted Delivery Terms: FOB, CFR, CIF, EXW. Accepted Payment Currency: USD, EUR, CNY. Accepted Payment Type: T/T, L/C, Western Union/Paypal/Credit card.

     

    6. How can you do the quality control?

    We had a professional QC team, which experience over 10 years. They take every progress controlled.

     

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now