Safety-First Latex Foley Catheter for Reliable Urethral Use

Product Details
Customization: Available
Type: Catheter
Material: Latex,Silicone Coated
Still deciding? Get samples of US$ 0.40/Piece
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 30 days
Quality Assurance
The supplier provides quality assurance
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
to see all verified strength labels (18)
  • Safety-First Latex Foley Catheter for Reliable Urethral Use
  • Safety-First Latex Foley Catheter for Reliable Urethral Use
  • Safety-First Latex Foley Catheter for Reliable Urethral Use
  • Safety-First Latex Foley Catheter for Reliable Urethral Use
  • Safety-First Latex Foley Catheter for Reliable Urethral Use
  • Safety-First Latex Foley Catheter for Reliable Urethral Use
Find Similar Products
  • Overview
  • Product Description
  • Product Specification
  • Product Picture
  • Hot Products
  • Certificate Display
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
Tiemann Two Way Latex Hard Valve 12Fr - 24Fr
Ethylene Oxide Sterilization
Ethylene Oxide Sterilization
Quality Guarantee Period
5 Years
Group
Adult
Logo Printing
With Logo Printing
Product Name
Latex 2-Way Tiemann Hard Valve Foley Catheter
Size
12fr -24fr
Valve
Hard Valve
Valve Material
Plastic Valve
Samples
Us $0.40 /Piece 1 Piece(Min.Order)
Certificate
CE/ISO
Box Specification
52.5X43X41 Cm
Storage Conditions
Store in Dark, Dry and Clean Conditions.
Packing
1PC/Blister Bag, 10PCS/Box, 500PCS/CTN
Transport Package
Corrugated Box
Trademark
Kind Rain
Origin
Guangdong, China
HS Code
9018390000
Production Capacity
1000000 PCS/Month

Product Description

Product Description

The Latex Urinary Tiemann Catheter is intended to be placed in the bladder, through the urethra, to drain urine into a collection device. Tiemann Foley balloon catheter is specially for urethral catheterization for those who suffer prostate hyperplasia and urthrostenosis.

Latex Urinary Catheter is made of nature latex, and the surface of the catheter is coated with a layer of pure silicone for a better biocompatibility.

 
 

Product Specification

Features
  • Color coded for size identification
  • Rubber valve & Plastic valve available
  • Tiemann tip for easy insertion
  • Close tip,with 2 drainage eyes
  • Fr12-24:length 40cm
Ref.NO. Size Balloon(ml/cc)
KR-LTC212HV 12Fr 5-10ml
KR-LTC214HV 14Fr 5-10ml
KR-LTC216HV 16Fr 5-10ml/30ml
KR-LTC218HV 18Fr 5-10ml/30ml
KR-LTC220HV 20Fr 5-15ml/30ml
KR-LTC222HV 22Fr 5-15ml/30ml
KR-LTC224HV 24Fr 30ml
 

Product Picture

Safety-First Latex Foley Catheter for Reliable Urethral UseSafety-First Latex Foley Catheter for Reliable Urethral UseSafety-First Latex Foley Catheter for Reliable Urethral UseSafety-First Latex Foley Catheter for Reliable Urethral UseSafety-First Latex Foley Catheter for Reliable Urethral UseSafety-First Latex Foley Catheter for Reliable Urethral Use
Contraindication
Patients with serious urethritis, serious urethral stricture, acute prostatitis, suspected with blunt or penetrating trauma-related urethral rupture shall be prohibited to use.

Warnings
  1. For single product and patient use only.
  2. Do not use product if the package is damaged.
  3. Do not re-use, reprocess or re-sterilize. Reuse may lead to infection. Reprocessing or Re-sterilization may damage the catheter and affect its integrity which when re-used may lead to possible deterioration in health and safety of patients.
Precautions
  1. Please read the instruction carefully before use.
  2. This procedure must be carried during complete aseptic technique.
  3. The catheter is for single use.
  4. Do not use catheter when it expires.
  5. Only the medical persons are allowed for operation.
  6. A lubricant containing petroleum base can not be used.
  7. The neleton catheter should not be more than 24 hours. The two-way and three-way catheter should not be used more than 7 days.
  8. Catheterization process should be aseptic.
  9. For two-way catheter and three-way catheter, the balloon should be inflated with sterile water and the inflated water can't exceed the marked volume.
Directions for use
Two-way type (Foley catheter)
Prepare the catheter for patient use
1. Remove catheter from its sterile pouch using an aseptic technique visually inspect the catheter for any mechanical damage. If a trial inflation of the balloon is carried out ensure the balloon to insertion. Only sterile water should be used to fill the balloon.
Insert and remove the catheter
2. Inform patient or their family the cause to use foley catheter, use methods, possible discomfort, methods to ease discomfortable symptom , possible complication and nursing after catheterization.
3. Check size and specification if it is correct, check the package and balloon whether they are damaged.
4. Inform patient to take a deep breath when insert the catheter. Before use of the product, wash hands thoroughly with soap and water.
5. Connect the catheter with urine bag and release the foley catheter.
6. Disinfect the patient's perineum.
7. Choose right lubricant to lubricate the catheter.
8. Insert the foley catheter gently. When urine start comes out, insert 5cm~6cm more.
9. Inflate the balloon with appropriate volume sterile water, pull out the catheter gently.

Remove the catheter
1. Explain the procedure to the patient.
2. Before catheter removal, wash hands thoroughly with soap and water and wear clean gloves.
3. Position patient and place waterproof pad under patient.
4. To deflate catheter balloon: Push a syringe without needle into the valve. Back off luer lock or slip tip syringe to 0.5mL and insert into the inflation port. Allow the pressure within the balloon to force the plunger back and fill the syringe with water (if slow or no deflation is noticed, re-seat the syringe gently).Use only gentle aspiration to encourage deflation if needed as vigorous aspiration may collapse the inflation lumen, preventing balloon deflation.
5. If the balloon doesn't deflate and permitted by hospital protocol, the valve arm may be severed. If this fails, contact adequately trained professional for assistance, as directed by hospital protocol.
6. If balloon rupture occurs, care should be taken to assure that all balloon fragments have been removed from the patient.
7. Deflate the balloon by inserting the syringe into the inflation valve, close the catheter or urine bag and gently pull out the catheter.

Product safe disposal
Used Catheter and its handling of accessories should be disposed in sanitary container to prevent possible contamination and cross infection.

Sterile Expiration Date
The expiration date is 5 years after sterilization.

Storage
Store at room controlled temperature. Do not expose to organic solvents, ionizing radiation or ultraviolet light.

 

Hot Products

Safety-First Latex Foley Catheter for Reliable Urethral Use Safety-First Latex Foley Catheter for Reliable Urethral Use Safety-First Latex Foley Catheter for Reliable Urethral Use Safety-First Latex Foley Catheter for Reliable Urethral Use
Safety-First Latex Foley Catheter for Reliable Urethral Use Safety-First Latex Foley Catheter for Reliable Urethral Use Safety-First Latex Foley Catheter for Reliable Urethral Use Safety-First Latex Foley Catheter for Reliable Urethral Use

Certificate Display

Safety-First Latex Foley Catheter for Reliable Urethral Use

Packaging & Shipping

Safety-First Latex Foley Catheter for Reliable Urethral Use

FAQ

1. Why choose us?

We have complete certificate CE/ISO/FSC etc. We are a good brand and have Competitive price & Fast leading time. Best service & Good reputation.

 

2. How can get your samples?

We provide free samples if the sample value is not much.

 

3. How fast can we get the goods?

Usually the production time is 30 days.

 

4. Can you do OEM printing?

Yes, we can offer OEM service. You can also choose Kind Rain brand or neutral English packing.

 

5. What services can we provide?

Accepted Delivery Terms: FOB, CFR, CIF, EXW. Accepted Payment Currency: USD, EUR, CNY. Accepted Payment Type: T/T, L/C, Western Union/Paypal/Credit card.

 

6. How can you do the quality control?

We had a professional QC team, which experience over 10 years. They take every progress controlled.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier