CE Approval Disposable Urethral Catheter Tray with Latex Foley Catheter
|
Still deciding? Get samples of $ !
Request Sample
|
Product Details
| Customization: | Available |
|---|---|
| Type: | Urology |
| Material: | Latex,Silicone Coated |
Diamond Member Since 2024
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Importers and Exporters
Fast Delivery
Quality Assurance
QA/QC Inspectors
The supplier has import and export rights
The supplier can deliver the goods within 30 days
The supplier provides quality assurance
The supplier has 1 QA and QC inspection staff
Sign In to see all verified strength labels (18)
Find Similar Products
Basic Info.
- Model NO.
- Latex 8Fr-26Fr
- Ethylene Oxide Sterilization
- Ethylene Oxide Sterilization
- Quality Guarantee Period
- 3 Years
- Group
- Pediatric,Adult
- Logo Printing
- With Logo Printing
- Product Name
- Latex Foley Catheter Kit
- Sizes Available
- 8fr-26fr
- Certificate
- CE/ISO Compliant
- Box Specification
- 53.5 X 47 X 33 Cm
- Storage Conditions
- Store in Dark, Dry and Clean Conditions.
- Packaging Details
- 1 Pack/Blister Bag, 40 Packs/CTN
- Transport Package
- Corrugated Box
- Trademark
- Kind Rain
- Origin
- Guangdong, China
- HS Code
- 9018390000
- Production Capacity
- 1000000 PCS/Month
Product Description
Materials and Structure:
Disposable Urethral Catheter Tray(Latex) is composed of a syringe (filled with purified water, not for injection), a catheter, a catheter clamp, a plastic tweezer, a plastic test tube with a stopper, a hole towel, a dressing towel, gauze pads, a water stop, lubricant, a drainage bag, a tray, iodine-containing cotton balls, and gloves.
| Size | Balloon Capacity |
| 8Fr | 3cc |
| 10Fr | 3cc/5cc |
| 12Fr-18Fr | 5cc/10cc/30cc |
| 20Fr-24Fr | 30cc |
| Components | Standard type | Common type | Basic type | Customized type |
| Foley catheter | √ | √ | √ | √ |
| Drainage tube | √ | √ | √ | √ |
| Glove | √ | √ | √ | √ |
| Catheter clamp | √ | / | / | Choose components according to contract |
| Plastic forceps | √ | √ | / | |
| Syringe | √ | √ | / | |
| PVP-I cotton balls | √ | / | / | |
| Plastic test tube | √ | / | / | |
| Fenestrated drape | √ | √ | / | |
| Surgical drape | √ | √ | / | |
| Lubricant | √ | √ | / | |
| Gauze pads | √ | / | / | |
| Water stopper | √ | / | / | |
| Tray | √ | √ | / |



Scope of application
Used by medical institutions for catheterization, urine collection, and sampling of patients.
Instruction for Use
- Inform patients or family members of the reasons, methods, possible discomfort, ways to alleviate discomfort, possible complications, and nursing cooperation after catheterization.
- Check the specification, and check whether the package is damaged, and whether the Foley catheter balloon is damaged.
- Instruct the patient to breathe deeply during intubation.
- Disinfect the patient's perineum.
- Connect the Foley catheter with the urine bag and open the Foley catheter.
- Select a suitable lubricant to lubricate the Foley catheter.
- Gently insert the Foley catheter, and then insert 5cm-6cm after the urine is seen.
- Inject sterile water of appropriate volume into the balloon, and gently pull the Foley catheter outward until resistance is encountered.
- When it is necessary to pull out the tube, use a syringe to drain the fluid in the balloon first. Do not drainage forcely, which will cause the balloon to fold and make it difficult to pull out the tube. Gently pull the Foley catheter out.
Contraindication
- Those who are allergic to natural rubber should use it with caution;
- Those with severe Urethritis, severe urethral stricture, acute Prostatitis, or urethral rupture related to blunt or penetrating trauma are prohibited.
Precautions, Warnings, and Indicative Notes
- This product is only for one-time use. Please read the manual carefully before use. It is prohibited to use after the expiration date;
- This product is only for medical personnel to operate and use;
- This product has been sterilized with ethylene oxide. If the packaging is damaged, do not use it;
- Lubricants containing petroleum base must not be used;
- Select the appropriate Foley catheter size. For children or urethral stricture, the Foley catheter size should be small;
- When inserting the catheter, the action should be gentle to avoid damaging the urethral mucosa. Do not insert too deep or too shallow, especially repeatedly twitching the Foley catheter;
- When using, please strictly follow the Aseptic technique. Only sterile water can be injected into the balloon, and the amount of water injected shall not exceed the marked capacity; When injecting water into the balloon, it is not advisable to inflate the balloon too quickly;
- If the bladder is overfilled and the patient is extremely weak, urination should be slow, and the first urination volume should not exceed 1000mL to avoid sudden bladder decompression causing bleeding or fainting;
- When measuring residual urine, instruct the patient to urinate first and then catheterize. The normal residual urine volume is 5-10mL. If it exceeds 100mL, catheterization should be performed;
- When indwelling catheterization, the fixation of the Foley catheter should be checked frequently to see if it is out of place. It is recommended to replace the Foley catheter according to clinical nursing norms or evidence-based. When reinserting, the urethra should be relaxed for a few hours before reinserting;
- If there is resistance when pulling out the Foley catheter, do not pull it out forcefully, otherwise the urethra will be damaged;
- When pulling out the Foley catheter, the empty syringe can be inserted into the valve according to the water injection method to allow the water to drain naturally, or the piston can be cut off to drain naturally before pulling out. If there is resistance, do not pull out forcefully, otherwise the urethra will be damaged;
- If it is found that the sterile water in the balloon cannot be discharged and other measures cannot be taken to discharge the sterile water, please contact the manufacturer in a timely manner and handle it under the guidance of the manufacturer. It is recommended to use a guide wire or take out the sterile water after undergoing perineal puncture under ultrasound;
- For patients with emotional instability or uncontrollable behavior, it is necessary to strengthen nursing. It is recommended to use a single lumen Foley catheter. If necessary, appropriate restrictions should be taken to prevent patients from pulling out the catheter by themselves, causing organic damage.
Product safe disposal
Used Urethral Catheter Tray(Latex) should be disposed of in sanitary container to prevent possible contamination and cross-infection.
Storage
Store in dry, ventilated and cool place, avoid exposure to harmful substances.


1. Why choose us?
We have complete certificate CE/ISO/FSC etc. We are a good brand and have Competitive price & Fast leading time. Best service & Good reputation.
2. How can get your samples?
We provide free samples if the sample value is not much.3. How fast can we get the goods?
Usually the production time is 30 days.4. Can you do OEM printing?
Yes, we can offer OEM service. You can also choose Kind Rain brand or neutral English packing.5. What services can we provide?
Accepted Delivery Terms: FOB, CFR, CIF, EXW. Accepted Payment Currency: USD, EUR, CNY. Accepted Payment Type: T/T, L/C, Western Union/Paypal/Credit card.6. How can you do the quality control?
We had a professional QC team, which experience over 10 years. They take every progress controlled.Send your message to this supplier