| TECHNICAL SPECIFICATION | |||
| Ventilation mode | Alarm and protection | ||
| PRVC, APRV, DUOLEVEL, V-SIMV, P-SIMV, P-A/C, V-A/C, | AC power failure alarm | Power failure or no connection | |
| IPPV, PCV, PSV, SPONT/CPAP, SIGH, MANUAL | Internal backup battery low voltage alarm | ≤ 11.3 ± 0.3 V | |
| No tidal volume | No tidal volume within 6 s | ||
| Ventilator parameter range | High minute volume alarm | 5 L/min ~ 99 L/min | |
| Tidal volume (Vt) | 0, 20 ~ 2000 mL | Low minute volume alarm | 1 L/min ~ 30 L/min |
| Frequency (Freq) | 1 min ~ 100 min | High airway pressure alarm | 20 cmH2O ~ 100 cmH2O |
| Oxygen concentration | 21 % ~ 100 % | Low airway pressure alarm | 0 cmH2O ~ 20 cmH2O |
| I:E | 4 : 1 ~ 1 : 8 | High oxygen concentration alarm | 19 % ~ 100 % |
| PEEP | 0 cmH2O ~ 40 cmH2O | Low oxygen concentration alarm | 18 % ~ 99 % |
| Pressure triggering sensitivity (Ptr) | -20 cmH2O ~ 0 cmH2O(Based on PEEP) | Continuous pressure alarm | (PEEP + 1.5 cmH2O) over 16s |
| Flow trigger sensitivity (Ftr) | 0.5 L/min ~ 30 L/min | Suffocation warning | 5 ~ 60 s |
| Pressure control (PC) | 5 cmH2O ~ 80 cmH2O | Fan error | Show on screen |
| Pressure support (PS) | 0 cmH2O ~ 80 cmH2O | Oxygen deficit | Show on screen |
| SIGH | 0 (off) 1/100 ~ 5/100 | The maximum limited pressure | < 12.5 kPa |
| Apnea ventilation | OFF, 5 s ~ 60 s | ||
| Pressure limit | 20 cmH2O ~ 100 cmH2O | Working condition | |
| Gas source | O2, Air | ||
| Monitoring parameter | Pressure | 280 kPa - 600 kPa | |
| Frequency (Freq) | 0/min ~ 100/min | Voltage | 220 V ± 22 V |
| Tidal volume (Vt) | 0 mL ~ 2500 mL | Power frequency | 50 Hz ± 1 Hz |
| MV | 0 L/min ~ 99 L/min | Input power | 900 VA(With air compressor) |
| Airway pressure | 0 cmH2O ~ 100 cmH2O | 250 VA(Without air compressor) | |
| Dynamic lung compliance monitoring | 1 mL/cmH2O ~ 1000 mL/cmH2O | ||
| Oxygen concentration | 15 % ~ 100 % | Oscillogram | |
| P-T(Pressure-Time) | |||
| Wooden case packing size | F-T(Flow-Time) | ||
| Main engine: L 560 * W 560 * H 615 mm | V-T(Volume-Time) | ||
| G.W.: 32 KG N.W.: 19 KG | P-V Loop(Pressure-Volume Loop) | ||
| Air compressor: L 685 * W 690 * H 1140 mm | F-V Loop(Flow-Volume Loop) | ||
| G.W.: 98KG N.W.: 63 KG | P-F Loop(Pressure-Flow Loop) | ||