High-Quality Sterile PVC Tracheal Tube with Cuff for Medical Professionals
|
Still deciding? Get samples of $ !
Request Sample
|
Product Details
| Customization: | Available |
|---|---|
| Type: | Anesthesia & Respiratory |
| Material: | PVC |
Diamond Member Since 2024
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Importers and Exporters
Fast Delivery
Quality Assurance
QA/QC Inspectors
The supplier has import and export rights
The supplier can deliver the goods within 30 days
The supplier provides quality assurance
The supplier has 1 QA and QC inspection staff
Sign In to see all verified strength labels (18)
Find Similar Products
Basic Info.
- Model NO.
- Standard With Cuff 2.5mm-10.0mm
- Ethylene Oxide Sterilization
- Ethylene Oxide Sterilization
- Quality Guarantee Period
- 5 Years
- Group
- Adult, Pediatric
- Logo Printing
- With Logo Printing
- Product Name
- Standard Endotracheal Tube with Cuff
- Size
- 2.5mm-10.0mm
- Samples
- Us$ 0.35/Piece 1 Piece(Min.Order)
- Certificate
- CE/ISO
- Box Specification
- 42X38X32 Cm
- Storage Conditions
- Store in Dry, Ventilated and Cool Place.
- Packing
- 1PC/Blister Bag, 10PCS/Box, 100PCS/CTN
- Transport Package
- Corrugated Box
- Trademark
- Kind Rain
- Origin
- Guangdong, China
- HS Code
- 9018390000
- Production Capacity
- 1500000 PCS/Month
Product Description
The endotracheal tube is intended for oral or nasal intubation and for airway management.The endotracheal tube is sterile and designed for single-use only to prevent infections.






Intended purpose
The Endotracheal tube is intended into the trachea for the primary purpose of establishing and maintaining a patent airway and to ensure the adequate exchange of oxygen and carbon dioxide.
Suggested instruction for use-cuffed ETTs
Contraindication
Cautions
Product safe disposal
Used Endotracheal Tube and its handling of accessories should be disposed in sanitary container to prevent possible contamination and cross infection.
Sterilization
Product was sterilized by Ethylene Oxide and aseptically packaged.
Sterile Expiration Date
The expiration date is 5 years after sterilization.
Storage
Store in dry, ventilated and cool place, avoid exposure to harmful substances.
Features
- High volume,low pressure
- Murphy
- For anaesthesia and intensive care
- X-ray
| Specifications | Designated size (Nominal inside diameter)mm |
Nominal outside diameter mm |
Cuff nominal diameter mm |
Minimum length of tube, A(oral/nasal)mm |
| Cuffed 2.5mm | 2.5 | 3.7 | 7.5 | 140 |
| Cuffed 3.0mm | 3.0 | 4.6 | 7.5 | 160 |
| Cuffed 3.5mm | 3.5 | 5.3 | 10 | 180 |
| Cuffed 4.0mm | 4.0 | 5.9 | 12 | 200 |
| Cuffed 4.5mm | 4.5 | 6.4 | 12 | 220 |
| Cuffed 5.0mm | 5.0 | 7.0 | 15 | 240 |
| Cuffed 5.5mm | 5.5 | 7.6 | 15 | 270 |
| Cuffed 6.0mm | 6.0 | 8.2 | 22 | 280 |
| Cuffed 6.5mm | 6.5 | 8.8 | 22 | 290 |
| Cuffed 7.0mm | 7.0 | 9.4 | 22 | 300 |
| Cuffed 7.5mm | 7.5 | 10.0 | 24 | 310 |
| Cuffed 8.0mm | 8.0 | 10.7 | 26 | 320 |
| Cuffed 8.5mm | 8.5 | 11.3 | 26 | 320 |
| Cuffed 9.0mm | 9.0 | 12.0 | /28 | 320 |
| Cuffed 9.5mm | 9.5 | 12.7 | 28 | 320 |
| Cuffed 10.0mm | 10.0 | 13.3 | 28 | 320 |






Intended purpose
The Endotracheal tube is intended into the trachea for the primary purpose of establishing and maintaining a patent airway and to ensure the adequate exchange of oxygen and carbon dioxide.
Suggested instruction for use-cuffed ETTs
- Healthcare professionals should check patients'trachea at first, in order to select the appropriate specification and confirm that the ETTs should be inserted into trachea through the oral or nasal;
- Carefully remove the sterile tracheal tubes from its protective packaging;
- The patency of the main tube lumen should be visual checked prior to intubation;
- Check the cuff, pilot balloon and valve for leak-proofness and integrity prior to use (Insert a Luer syringe into the Luer adapter for the filling system and inject enough air to fully inflate the cuff);
- After the test inflation of the cuff, completely evacuate the air;
- Intubate the patient following currently accepted medical techniques, a laryngoscope should be used to check the inserted condition of endotracheal tubes;
- Once the patient is intubated, a Luer syringe or an appropriate VBM cuff pressure gauge should be used to inflate the cuff with just enough air to provide an effective seal of the trachea. The cuff pressure should normally not exceed 2.5kPa;
- Fix the tube of the patient following currently accepted medical techniques;
- Check that the inflating system is not leaking. Cuff pressure should be measured and the integrity of the system should be verified periodically during the intubation period. Any deviation from the selected sealing pressure should be investigated and corrected immediately;
- Patient conditions should be monitored during intubation period, and sputum should be cleaned;
- Prior to extubation, deflate the cuff by inserting a syringe into the cuff filling system and removing all of the air contained within the cuff until the pilot balloon has collapsed;
- Extubate the patient following currently accepted medical standards. Dispose of the tracheal tube.
Contraindication
- Throat edema
- Acute inflammation of trachea
- Tracheal compression of thoracic aortic aneurysm
- Severe bleeding
- Cervical spinal injuries
Cautions
- Single use only. Do not use when expired;
- Only for tracheal intubation trained healthcare personnel use;
- Intubation period should not exceed 30 days;
- Do not apply laser on the tube;
- The product is sterile, do not us if the package is opened or damaged;
- Choose the suitable specification of Endotracheal tube according to patient's age, sex, body size and other actual situation;
- After use, product and packaging should be disposed according to hospital requirement or environmental protection requirement.
Product safe disposal
Used Endotracheal Tube and its handling of accessories should be disposed in sanitary container to prevent possible contamination and cross infection.
Sterilization
Product was sterilized by Ethylene Oxide and aseptically packaged.
Sterile Expiration Date
The expiration date is 5 years after sterilization.
Storage
Store in dry, ventilated and cool place, avoid exposure to harmful substances.


1. Why choose us?
We have complete certificate CE/ISO/FSC etc. We are a good brand and have Competitive price & Fast leading time. Best service & Good reputation.2. How can get your samples?
We provide free samples if the sample value is not much.3. How fast can we get the goods?
Usually the production time is 30 days.4. Can you do OEM printing?
Yes, we can offer OEM service. You can also choose Kind Rain brand or neutral English packing.5. What services can we provide?
Accepted Delivery Terms: FOB, CFR, CIF, EXW. Accepted Payment Currency: USD, EUR, CNY. Accepted Payment Type: T/T, L/C, Western Union/Paypal/Credit card.6. How can you do the quality control?
We had a professional QC team, which experience over 10 years. They take every progress controlled.
Send your message to this supplier
People who viewed this also viewed
Product Groups
More
Find Similar Products By Category
- Supplier Homepage
- Products
- Anesthesia & Respiratory
- Endotracheal Tube
- High-Quality Sterile PVC Tracheal Tube with Cuff for Medical Professionals
Related Categories
Hot Searches
More