Premium Hygienic Single-Use PVC Tracheal Tube with Cuff

Product Details
Customization: Available
Type: Anesthesia & Respiratory
Material: PVC,Stainless Steel
Still deciding? Get samples of US$ 1.5/Piece
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 30 days
Quality Assurance
The supplier provides quality assurance
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
to see all verified strength labels (18)
  • Premium Hygienic Single-Use PVC Tracheal Tube with Cuff
  • Premium Hygienic Single-Use PVC Tracheal Tube with Cuff
  • Premium Hygienic Single-Use PVC Tracheal Tube with Cuff
  • Premium Hygienic Single-Use PVC Tracheal Tube with Cuff
  • Premium Hygienic Single-Use PVC Tracheal Tube with Cuff
  • Premium Hygienic Single-Use PVC Tracheal Tube with Cuff
Find Similar Products
  • Overview
  • Product Description
  • Product Specification
  • Product Picture
  • Hot Products
  • Certificate Display
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
Reinforced With Cuff 3.5mm-9.0mm
Ethylene Oxide Sterilization
Ethylene Oxide Sterilization
Quality Guarantee Period
5 Years
Group
Adult, Pediatric
Logo Printing
With Logo Printing
Product Name
Reinforced Endotracheal Tube with Cuff
Size
3.5mm-9.0mm
Samples
Us$ 1.5/Piece 1 Piece(Min.Order)
Certificate
CE/ISO
Box Specification
42X38X32 Cm
Storage Conditions
Store in Dry, Ventilated and Cool Place.
Packing
1PC/Blister Bag, 10PCS/Box, 100PCS/CTN
Transport Package
Corrugated Box
Trademark
Kind Rain
Origin
Guangdong, China
HS Code
9018390000
Production Capacity
500000 PCS/Month

Product Description

Product Description

The reinforced endotracheal tube is intended for airway management by oral or nasal intubation of the trachea during anesthesia. It is a device inserted into the trachea through the mouth or nose to facilitate breathing and it may be used where the patient's neck is likely to be moved of flexed or the patient is in the prone position so that a non-reinforced tracheal tube might become kinked.

The reinforced endotracheal tube is sterile and designed for single-use only to prevent infections.

Premium Hygienic Single-Use PVC Tracheal Tube with Cuff

Product Specification

Features
  • High volume,low pressure
  • Murphy
  • For anaesthesia and intensive care
  • X-ray
Specifications Designated size
(Nominal inside diameter)
Nominal outside diameter mm Cuff nominal diameter mm Minimum length of tube,A(oral/nasal) mm
Reinforced Cuffed 3.5mm 3.5 6.0 12 180
Reinforced Cuffed 4.0mm 4.0 6.7 12 200
Reinforced Cuffed 4.5mm 4.5 7.3 15 220
Reinforced Cuffed 5.0mm 5.0 7.7 15 240
Reinforced Cuffed 5.5mm 5.5 8.3 20 270
Reinforced Cuffed 6.0mm 6.0 9.0 20 280
Reinforced Cuffed 6.5mm 6.5 9.7 20 290
Reinforced Cuffed 7.0mm 7.0 10.3 23 300
Reinforced Cuffed 7.5mm 7.5 11.0 25 310
Reinforced Cuffed 8.0mm 8.0 11.7 25 320
Reinforced Cuffed 8.5mm 8.5 12.3 28 320
Reinforced Cuffed 9.0mm 9.0 13.0 28 320

    Product Picture

    Premium Hygienic Single-Use PVC Tracheal Tube with CuffPremium Hygienic Single-Use PVC Tracheal Tube with CuffPremium Hygienic Single-Use PVC Tracheal Tube with CuffPremium Hygienic Single-Use PVC Tracheal Tube with CuffPremium Hygienic Single-Use PVC Tracheal Tube with CuffPremium Hygienic Single-Use PVC Tracheal Tube with Cuff
    Intended purpose
    The Reinforced Endotracheal tube is intended into the trachea for the primary purpose of establishing and maintaining a patent airway and to ensure the adequate exchange of oxygen and carbon dioxide.

    Suggested instruction for use-Reinforced cuffed ETTs
    1. Healthcare professionals should check patients' trachea at first, in order to select the appropriate specification and confirm that the ETTs should be inserted into trachea through the oral or nasal;
    2. Carefully remove the sterile tracheal tubes from its protective packaging;
    3. The patency of the main tube lumen should be visual checked prior to intubation;
    4. Check the cuff, pilot balloon and valve for leak-proofness and integrity prior to use (Insert a Luer syringe into the Luer adapter for the filling system and inject enough air to fully inflate the cuff);
    5. After the test inflation of the cuff, completely evacuate the air;
    6. Intubate the patient following currently accepted medical techniques, a laryngoscope should be used to check the inserted condition of endotracheal tubes;
    7. Once the patient is intubated, a Luer syringe or an appropriate VBM cuff pressure gauge should be used to inflate the cuff with just enough air to provide an effective seal of the trachea. The cuff pressure should normally not exceed 2.5kPa;
    8. Fix the tube of the patient following currently accepted medical techniques;
    9. Check that the inflating system is not leaking. Cuff pressure should be measured and the integrity of the system should be verified periodically during the intubation period. Any deviation from the selected sealing pressure should be investigated and corrected immediately;
    10. Patient conditions should be monitored during intubation period, and sputum should be cleaned;
    11. Prior to extubation, deflate the cuff by inserting a syringe into the cuff filling system and removing all of the air contained within the cuff until the pilot balloon has collapsed;
    12. Extubate the patient following currently accepted medical standards. Dispose of the tracheal tube.

    Contraindication
    • Throat edema
    • Acute inflammation of trachea
    • Tracheal compression of thoracic aortic aneurysm
    • Severe bleeding
    • Cervical spinal injuries

    Cautions
    1. Single use only. Do not use when expired;
    2. Only for tracheal intubation trained healthcare personnel use;
    3. Intubation period should not exceed 30 days;
    4. Do not apply laser on the tube;
    5. The product is sterile, do not us if the package is opened or damaged;
    6. Choose the suitable specification of Endotracheal tube according to patient's age, sex, body size and other actual situation;
    7. After use, product and packaging should be disposed according to hospital requirement or environmental protection requirement.

    Product safe disposal
    Used Endotracheal Tube and its handling of accessories should be disposed in sanitary container to prevent possible contamination and cross infection.

    Storage
    Store in dry, ventilated and cool place, avoid exposure to harmful substances.
     

    Hot Products

    Premium Hygienic Single-Use PVC Tracheal Tube with Cuff Premium Hygienic Single-Use PVC Tracheal Tube with Cuff Premium Hygienic Single-Use PVC Tracheal Tube with Cuff Premium Hygienic Single-Use PVC Tracheal Tube with Cuff
    Premium Hygienic Single-Use PVC Tracheal Tube with Cuff Premium Hygienic Single-Use PVC Tracheal Tube with Cuff Premium Hygienic Single-Use PVC Tracheal Tube with Cuff Premium Hygienic Single-Use PVC Tracheal Tube with Cuff

    Certificate Display

    Premium Hygienic Single-Use PVC Tracheal Tube with Cuff

    Packaging & Shipping

    Premium Hygienic Single-Use PVC Tracheal Tube with Cuff

    FAQ

    1. Why choose us?

    We have complete certificate CE/ISO/FSC etc. We are a good brand and have Competitive price & Fast leading time. Best service & Good reputation.

     

    2. How can get your samples?

    We provide free samples if the sample value is not much.

     

    3. How fast can we get the goods?

    Usually the production time is 30 days.

     

    4. Can you do OEM printing?

    Yes, we can offer OEM service. You can also choose Kind Rain brand or neutral English packing.

     

    5. What services can we provide?

    Accepted Delivery Terms: FOB, CFR, CIF, EXW. Accepted Payment Currency: USD, EUR, CNY. Accepted Payment Type: T/T, L/C, Western Union/Paypal/Credit card.

     

    6. How can you do the quality control?

    We had a professional QC team, which experience over 10 years. They take every progress controlled.

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now
    Contact Supplier