• Disposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral Catheter
  • Disposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral Catheter
  • Disposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral Catheter
  • Disposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral Catheter
  • Disposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral Catheter
  • Disposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral Catheter

Disposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral Catheter

Type: Catheter
Material: 100% Medical Grade Silicone
Ethylene Oxide Sterilization: Ethylene Oxide Sterilization
Quality Guarantee Period: 5 Years
Group: Adult
Logo Printing: With Logo Printing
Samples:
US$ 1.6/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2024

Suppliers with verified business licenses

Guangdong, China
Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 30 days
Quality Assurance
The supplier provides quality assurance
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
to see all verified strength labels (18)
  • Overview
  • Product Description
  • Product Specification
  • Product Picture
  • Hot Products
  • Certificate Display
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
Integrated balloon, Two Way Silicone 12Fr - 24Fr
Product Name
Integrated Balloon Silicone 2-Way Foley Catheter
Size
12fr -24fr
Valve
Hard Valve
Valve Material
Plastic Valve
Samples
Us$ 1.6 /Piece 1 Piece(Min.Order)
Certificate
CE/ISO
Box Specification
52.5X43X41 Cm
Customization
Available
Storage Conditions
Store in Dark, Dry and Clean Conditions.
Packing
1PC/Blister Bag, 10PCS/Box, 500PCS/CTN
Transport Package
Corrugated Box
Trademark
Kind Rain
Origin
Guangdong, China
HS Code
9018390000
Production Capacity
300000 PCS/Month

Product Description

Product Description

The Silicone Urinary Catheter with integrated balloon is made of 100% medical grade silicone. It consists of drainage funnel, balloon, inflation lumen, tube shaft, drainage hole, balloon and inflation valve.

Type: two-way integrated balloon catheter 

The Silicone Urinary Catheter with integrated balloon is intended to be placed in the bladder, through the urethra, to drain urine into a collection device. Two-way catheters are intended for urological bladder drainage only.

Contraindication
Patients with serious urethritis, serious urethral stricture, acute prostatitis, suspected with blunt or penetrating trauma-related urethral rupture shall be prohibited to use.

Warnings
  1. For single product and patient use only.
  2. Do not use product if the package is damaged.
  3. Do not re-use, reprocess or re-sterilize. Reuse may lead to infection. Reprocessing or Re-sterilization may damage the catheter and affect its integrity which when re-used may lead to possible deterioration in health and safety of patients.

Precautions
  1. Please read the instruction carefully before use.
  2. This procedure must be carried during complete aseptic technique.
  3. The catheter is for single use.
  4. Do not use catheter when it expires.
  5. Only the medical persons are allowed for operation.
  6. A lubricant containing petroleum base can not be used.
  7. The catheter should be used for less than 30 days.
  8. Catheterization process should be aseptic, the balloon should be inflated with sterile water and the inflated water can't exceed the marked volume.

Product Specification

Features
  • Color coded for size identification
  • Integrated balloon reduce catheterization pain
  • Close tip,with 2 drainage eyes
  • Fr12-24:length 40cm
Ref.NO. Size Balloon(ml/cc)
KR-SFC512 12Fr 5ml/5-10ml
KR-SFC514 22Fr 5-10ml
KR-SFC516 14Fr 5-10ml
KR-SFC518 16Fr 5-10ml
KR-SFC520 18Fr 5-10ml
KR-SFC522 20Fr 5-10ml
KR-SFC524 24Fr 5-10ml

Directions for use
Prepare the catheter for patient use
1. Remove catheter from its sterile pouch using an aseptic technique visually inspect the catheter for any mechanical damage. If a trial inflation of the balloon is carried out ensure the balloon to insertion. Only sterile water should be used to fill the balloon.
Insert and remove the catheter
2. Inform patient or their family the cause to use foley catheter, use methods, possible discomfort, methods to ease discomfortable symptom , possible complication and nursing after catheterization.
3. Check size and specification if it is correct, check the package and balloon whether they are damaged.
4. Inform patient to take a deep breath when insert the catheter. Before use of the product, wash hands thoroughly with soap and water.
5. Connect the catheter with urine bag and release the foley catheter.
6. Disinfect the patient's perineum.
7. Choose right lubricant to lubricate the catheter.
8. Insert the foley catheter gently. When urine start comes out, insert 5cm~6cm more.
9. Inflate the balloon with appropriate volume sterile water, pull out the catheter gently until you feel resistance.

Remove the catheter
1. Explain the procedure to the patient.
2. Before catheter removal, wash hands thoroughly with soap and water and wear clean gloves.
3. Position patient and place waterproof pad under patient.
4. To deflate catheter balloon: Push a syringe without needle into the valve. Back off luer lock or slip tip syringe to 0.5mL and insert into the inflation port. Allow the pressure within the balloon to force the plunger back and fill the syringe with water (if slow or no deflation is noticed, re-seat the syringe gently).Use only gentle aspiration to encourage deflation if needed as vigorous aspiration may collapse the inflation lumen, preventing balloon deflation.
5. If the balloon doesn't deflate and permitted by hospital protocol, the valve arm may be severed. If this fails, contact adequately trained professional for assistance, as directed by hospital protocol.
6. If balloon rupture occurs, care should be taken to assure that all balloon fragments have been removed from the patient.
7. Deflate the balloon by inserting the syringe into the inflation valve, close the catheter or urine bag and gently pull out the catheter.

Product safe disposal
Used Catheter and its handling of accessories should be disposed in sanitary container to prevent possible contamination and cross infection.

Sterile Expiration Date
The expiration date is 5 years after sterilization.

Storage
Store at room controlled temperature. Do not expose to organic solvents, ionizing radiation or ultraviolet light.
 

Product Picture

Disposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral CatheterDisposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral CatheterDisposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral CatheterDisposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral CatheterDisposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral CatheterDisposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral Catheter

Hot Products

Disposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral Catheter Disposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral Catheter Disposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral Catheter Disposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral Catheter
Disposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral Catheter Disposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral Catheter Disposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral Catheter Disposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral Catheter

Certificate Display

Disposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral Catheter

Packaging & Shipping

Disposable Medical 2-Way Sterile Integrated Balloon Silicone Foley Catheter Urethral Catheter

FAQ

1. Why choose us?

We have complete certificate CE/ISO/FSC etc. We are a good brand and have Competitive price & Fast leading time. Best service & Good reputation.

 

2. How can get your samples?

We provide free samples if the sample value is not much.

 

3. How fast can we get the goods?

Usually the production time is 30 days.

 

4. Can you do OEM printing?

Yes, we can offer OEM service. You can also choose Kind Rain brand or neutral English packing.

 

5. What services can we provide?

Accepted Delivery Terms: FOB, CFR, CIF, EXW. Accepted Payment Currency: USD, EUR, CNY. Accepted Payment Type: T/T, L/C, Western Union/Paypal/Credit card.

 

6. How can you do the quality control?

We had a professional QC team, which experience over 10 years. They take every progress controlled.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2024

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 13485, FSC